3. set the pulse instruction form
Parameter
Meaning
setting
Meaning
Change
Effective
P0-10
n.xxx□
Pulse
command
form
0
CW, CCW mode
Servo
OFF
At once
1
AB phase
2
Pulse + direction (defaulted)
P0-10
n.xx□x
Effective
edge of
pulse
signal
0
falling edge is valid
4. Logical form of instruction pulse
P0-10.0
Forward rotation
Reverse rotation
0CW/CCW
CCW
CW
OFF
CCW
CW
OFF
1AB
90°
Phase A
Phase B
90°
Phase A
Phase B
2P+D
pulse
direction
ON
pulse
direction
OFF
5. Pulse specification
Pulse specification
Highest input
frequency
Voltage
Forward current
Low speed pulse
Differential signal
500Kpps
3.3~5V
<25mA
Open collector
200Kpps
24V
<25mA