P7- Function Unit
Default
value
Range Effective Suitable mode
12
2M
13
3M
14
4M
15
5M
16
6M
01.2
RS485 stop bit
0
2 bits
2
1 bit
Stop bit 2 0~2 1|3|5|6|7|8|9|10
01.3
RS485 parity bit
0-no parity
1-odd parity
2-even parity
Parity bit 2 0~2 1|3|5|6|7|8|9|10
02
RS485 communication protocol
1-Modbus Rtu protocol
2-Xnet bus protocol
3-read Xnet bus torque
- 1 1~255 1|3|5|6|7|8|9|10
03
Xnet Synchronized sampling
time
1ms 9 1~500 10
04 Xnet slave station data - 15 1~500 10
05 Xnet slave station numbers - 10 1~20 10
06
Number of communication
overtime retries
times 10 1~500 10
07 Bus instruction refresh cycle 1us 3000 1~65535 10
08
Compensation Threshold of
Position Deviation
- 0 0~0 10
09
Compensation times for Position
Deviation
- 0 0~0 10
10 RS232 station no. - 1 0~100 1|2|3|4|5|6|7|10
11.0~1 RS232 baud rate Baud rate 06 0~16 1|2|3|4|5|6|7|10