Note: the rising edge of P5-35 step change signal triggers each position (the rising edge 
is invalid during operation). 
1. When the servo enable is off during a certain section of operation, the motor stops 
according  to  the  servo  off  shutdown  mode.  After  the  shutdown,  the  positioning  is 
invalid. 
2. The adjustment time is not valid in this mode. 
3. After each operation completion, positioning completion and positioning approach 
signal are all effective. 
4. After the segment number is selected, the rising edge of P5-35/CHGSTP step change 
signal is required to trigger to run the position segment, and the step change triggering 
during segment operation is invalid. 
5. Segment number selection terminal logic is voltage level valid. Input high voltage 
level is valid, input low voltage level is invalid. 
3. Positioning mode