V5 series inverter 
15 
2 Installation and Wiring 
2-1. Installation environment 
2-1-1. Environment requirement 
  Ambient tempeature: -10ºC~40ºC. The inverter should be derated when the temperature over 40ºC, at the same time 
ventilation and heat dissipation should be enhanced. 
  Far away from the location with direct sunlight, dust, floating fiber or metal powder. 
  Mount in the location free of corrosive gas and combustible gas. 
  Mount in the location free of condensation, and the humidity should less then 95%RH.     
  Mount in the location where vibration less than 5.9m/s²(0.6G)   
  Far away from electramagnetism interfere source and other electric instruments sensitive with electramagnetism in-
terfere. 
2-1-2. Mounting location and space 
  Mount the inverter vertically under general condition. 
  The mounting space and distance are shown in Fig. 2-1. 
  When several inverters are mounted up and down, air diversion plate should be fixed in the middle as shown in Fig. 
2-2. 
 
       
            Fig. 2-1 Mounting Space            Fig.2-2 Mounting of Multi-Inverters 
2-1-3. Mounting and removing 
  Removing: Romove the four screws on the cover with phillips screwdriver   
  Mounting: Allign the mounting holes and then fix the screws. 
 
 
 
 
 
 
 
 
 
 
 
 
Air diverting 
plate