Swing adds a swing/groove to the global mainclock with a +- 1/64th precision. Please note that the
clock outputs are also affected by the swing.
Transpose Change the global transpose in semitones/octaves higher and lower the regular pitch.
When changing the values with SHIFT+CURSOR LEFT/RIGHT, then the new transpose value will
be set on a zero transition of the mainclock if the sequencer if it is running. Pressing OK will
change the transpose value immediately. Holding OK while SHIFT+ CURSOR LEFT/RIGHT will
also change the transpose immediately.
Load Menu Opens a file browser to load a project
Save As Save a project. A on-screen keyboard will appear to either save the current project (just
press OK on the READY field) or enter a new project name and save it with pressing OK on the
READY field. An existing project will be overwritten after a backup is being created into the backup
folder (10 iterations).
Load Sample opens the sample-slot window.
Load Sampleblock and
Save Sampleblock are used to load and save complete sample blocks. A sample block are all 12
sample slots together. Here you can recall the whole block (eg replace all samples in one
go). This can also be loaded nearly seamlessly while running a sequence using a
command in the sample FX.
Sample block 000 is not supported, so every sample block must at least be named 1 and
higher.
Track Assign enters the → Track Assign Screen screen. This is used to assign different track
types to the tracks. For example a regular CV/Gate track can be set to be a Midi track, Trigger16 ,
CV16 or any other type to use it’s dedicated functionality.
Clock IN For the Main clock input setting. Those are:
Internal - Sequencer runs from the internal clock at 24ppqn internally
Mod. Clock24 - Sequencer runs from the Clock/Reset input with a resolution of 24ppqn
Mod. Clock - Sequencer runs from the Clock/Reset input with 1/16 resolution
Midi - Sequencer runs from external Midi Clock as follower (Midi-IO Expander / TRS-A Midi
expander module needed)
DIN-Sync – Sequencer runs from external DIN-Sync signals while the clock input is the Din-
Sync clock signal and the reset input is the Din-Sync run/start/stop signal. The continue
signal is not supported.
NerdSEQ – a tracker based Eurorack sequencer Page 83