4. Reconnect A3-P1, A3-E1 & A3-E2 and A3-E6 (if used) to the active high
voltage module. Disconnect the HV wires from cable clamp, and connect the
high voltage wire(s) to JHV1 of A2 and JHV2 (if used). Reconnect J1 wire
to A3-E5.
Warning! For continued safety A3-E1 & A3-E2 must be properly reinstalled!
5. Replace the top cover.