Series EJ, ET, EY, FJ & FR
102002-177 Rev M2
31
\1020\02177M2.doc 17 Jun 2019
CONTROL LOCK Indicator:
Amber LED that illuminates when the front panel CONTROL LOCK function is
active.
VOLTAGE and CURRENT Encoders:
Infinitely variable multi-turn controls to control the voltage and current from zero to
rated. Since there are no mechanical stops the PRESET function enables
determining their settings. Turning the encoder past its end of range will not
advance or reduce the output any further. The encoder will continue to turn but the
output will remain at the maximum or minimum rated value.
When in local mode, upon power-up, the encoders will both be set to the last settings
of the encoders at the prior power down. When switching from local to remote mode
the control settings will be retained so that when it is switched back to local the
output settings will return to the former values.