Series EJ, ET, EY, FJ & FR
102002-177 Rev M2
6
\1020\02177M2.doc 17 Jun 2019
J4 AC POWER INPUT
EJ, FR & FJ units operate off single phase 115 or 230 VAC as selected by S3 (see
figure above). For models without selector switch, consult model label for correct
input voltage. ET and EY units operate from 230 VAC only.
WARNING! The ground (center) terminal of this input should be connected to
the AC outlet ground or other good earth ground.
For EJ, FR, & FJ units, J4 is an IEC C14 receptacle. Mating line cords are provided
for both 115VAC and 230VAC operation. The 115VAC line cord has a plug for a
NEMA 5-15 grounded outlet and the 230VAC line cord has a plug for a NEMA 6-15
grounded outlet. In other regions, the appropriate plug or IEC cord set should be
substituted.
For ET units, J4 is an IEC C20 receptacle. A mating line cord is provided with a plug
for a NEMA 6-20P grounded outlet. In other regions, the appropriate plug or IEC
cord set should be substituted.
For EY units, J4 is an IEC C14 receptacle. A shielded mating line cord is provided
with a plug for a NEMA 6-15P grounded outlet. In other regions, the appropriate
plug or IEC shielded cord set should be substituted.
If the plug is removed from the cord provided, the wires should be connected as
follows:
Green/Yellow - Ground
Brown - Line
Blue - Line or Neutral
Shield - Ground (if applicable)
Check to see that your input line voltage matches the rating of the supply before
applying power.
For CE compliant supplies used in Europe:
Please refer to the Declaration of Conformity located elsewhere in this manual
for installation environment conditions required to conform to 2014/35/EU
(Low Voltage Directive).
POWER ON INDICATOR
WARNING! When this lamp is illuminated, power supply is turned on. Do not
apply or remove any connections to this unit until AC power is removed and the
DC output has discharged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the XP GLASSMAN EJ Series and is the answer not in the manual?

XP GLASSMAN EJ Series Specifications

General IconGeneral
BrandXP
ModelGLASSMAN EJ Series
CategoryPower Supply
LanguageEnglish

Related product manuals