User manual V4.6.0 49
Access
level
Param.
Denomination / description
Fact. value
2
Mod.
value
Expert
1256
Delay to deactivate (AUX 1)
60 min
Expert
1258
Inverter power level 1 activate (AUX 1)
No
Expert
1259
Power level 1 (AUX 1)
120 % Pnom
Expert
1260
Time delay 1 (AUX 1)
1 min
Expert
1261
Inverter power level 2 activate (AUX 1)
No
Expert
1262
Power level 2 (AUX 1)
80 % Pnom
Expert
1263
Time delay 2 (AUX 1)
5 min
Expert
1264
Inverter power level 3 activate (AUX 1)
No
Expert
1265
Power level 3 (AUX 1)
50 % Pnom
Expert
1266
Time delay 3 (AUX 1)
30 min
Expert
1267
Inverter power level to deactivate (AUX 1)
40 % Pnom
Expert
1268
Time delay to deactivate (AUX 1)
5 min
Expert
1271
Day of the week (AUX 1)
None days
Expert
1272
Start hour (AUX 1)
07:00 hh:mm
Expert
1273
End hour (AUX 1)
20:00 hh:mm
Expert
1275
Day of the week (AUX 1)
None days
Expert
1276
Start hour (AUX 1)
07:00 hh:mm
Expert
1277
End hour (AUX 1)
20:00 hh:mm
Expert
1279
Day of the week (AUX 1)
None days
Expert
1280
Start hour (AUX 1)
07:00 hh:mm
Expert
1281
End hour (AUX 1)
20:00 hh:mm
Expert
1283
Integral mode
No
Expert
1284
Equalization with fixed interval
No
Expert
1285
Weeks between equalizations
26 weeks
Expert
1286
AC Output voltage
230 Vac
Inst.
1287
Restore factory settings
-
Expert
1288
Use dynamic compensation of battery level (AUX 1)
Yes
Expert
1290
Equalization current
60 Adc
Expert
1291
Equalization before absorption phase
Yes
Expert
1295
Charge current decrease coef. at voltage limit to turn
back in inverter mode
100%
Expert
1296
Batteries priority as energy source
No
Expert
1297
Battery priority voltage
12.9/25.8/51.6 Vdc
Expert
1298
Increment step of the adaptive low voltage
0.1/0.2/0.5 Vdc
Expert
1304
Number of batteries undervoltage allowed before
definitive stop
3
Expert
1305
Number of batteries critical undervoltage allowed
before definitive stop
10
Expert
1307
Reset voltage for adaptive correction
13.2/26.4/52.8 Vdc
Expert
1309
AC input low limit voltage to allow charger function
180 Vac
Expert
1311
Operating mode (AUX 2)
Reversed
automatic
Expert
1314
Day of the week (AUX 2)
None days
Expert
1315
Start hour (AUX 2)
07:00 hh:mm
Expert
1316
End hour (AUX 2)
20:00 hh:mm
Expert
1318
Day of the week (AUX 2)
None days
Expert
1319
Start hour (AUX 2)
07:00 hh:mm
Expert
1320
End hour (AUX 2)
20:00 hh:mm
Expert
1322
Day of the week (AUX 2)
None days
Expert
1323
Start hour (AUX 2)
07:00 hh:mm
Expert
1324
End hour (AUX 2)
20:00 hh:mm
Inst.
1326
Day of the week (AUX 2)
None days
Inst.
1327
Start hour (AUX 2)
07:00 hh:mm
Inst.
1328
End hour (AUX 2)
20:00 hh:mm
Inst.
1330
Day of the week (AUX 2)
None days