Country Electrical Data
Switzerland 6 A, 250 V, AC
Sweden 10 A, 230 V, AC Resistive load
3A, 250 V, AC Inductive load
5 A, 30 V, DC Resistive load
*1 mA, 5 V, DC, Gold Contact
* Part no: 594 79 19 & 594 79 20
Safety data for EX approved installation
Maximum input voltage, U
i
: 30 V
Maximum input current, I
i
: 100 mA
Maximum input power, P
i
: 1.2 W
Depth of immersion: Max 20 m
For cable length 20 m:
Maximum internal capacitance, C
i
: 1.8 nF
Maximum internal inductance, L
I
: 10 μH
Approvals
CE, CSA, SEMKO, NEMKO, DEMKO, EX
LVD approval according to EN61058
CSA approval: Cert no. 1330172
Cl.I Zone 0, Gr. IIC;
CL.I Div.1 Gr A, B, C&D
Cl.II Gr. E, F&G
Cl.III when installed to the certified Intrinsically Safe relay, Ex ia, rated for the locations per
submitter control drawing and installation manual.
Ex approval:
IECEx ia IIC T4 Ga: -20°C<Ta<60°C
IECEx NEMKO 09.008
ATEX II 1G ia IIC T4
NEMKO 10ATEX 1082
The applied standards are:
EN 60079-0:2009/IEC 60079-0:2007
EN 60079-11:2007/IEC 60079-0:2006
EN 60079-26:2007/IEC 60079-26:2006
Intrinsically safe circuits are required for the automatic control system. - Use a EX-safety
barrier (e.g. Prod. no. 84 01 07).
0080
R
Safety
Flygt ENM 10 Level regulator Installation, Operation and Maintenace Manual 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Flygt ENM 10 and is the answer not in the manual?

Xylem Flygt ENM 10 Specifications

General IconGeneral
BrandXylem
ModelFlygt ENM 10
CategoryController
LanguageEnglish

Related product manuals