en Original Instructions
e-SHE, e-SHS
Additional Installation, Operation and Maintenance Instructions 19
4.2.4 Fastening of the unit
Phase
Action
Illustration
1
If present, remove the plugs covering the suction and discharge ports.
2
Place the unit on the foundation.
3
Align the suction and discharge ports to their piping.
4a
Unit with foot on the pump:
secure with 3 bolts with resistance class 8.8 or higher.
4b
Unit with foot on the motor:
secure with 4 bolts with resistance class 8.8 or higher.
4c
Unit with motor size from 160 to 200, 2 poles and 160, 4 poles:
insert the 2 shims and secure with 4 bolts with resistance class 8.8 or
higher.
4.2.5 Reducing vibrations
The motor and the flow of liquids in the pipes may cause vibrations, which can be exacerbated
by incorrect installation of the unit and pipes. See Hydraulic connection on page 20.