8 Technical Information
8.1 Operating environment
Non-aggressive and non-explosive atmosphere.
Temperature
The table shows the temperatures according to the motor characteristics.
Phase ~
Number of poles
Power, kW
Temperature, °C (°F)
1
All
0 - 40 (32 - 104)
3
4
0.25 to 0.75
1.1 to 15.0
0 - 50 (32 - 122)
2
0.75 to 22.0
NOTICE: Danger of motor overheating
If the unit is exposed to temperatures higher than
those indicated, reduce the motor power; see
Downgrading the motor.
Otherwise, replace the motor with a more powerful one.
Relative air humidity
< 50% at 40°C (104°F).
NOTICE:
If the humidity exceeds the stated limits, contact Xylem or the Authorised Distributor.
Elevation
< 1000 m (3300 ft) above sea level.
NOTICE: Danger of motor overheating
If the unit is exposed to temperatures higher than those indicated, reduce the motor power;
see
Downgrading the motor.
Otherwise, replace the motor with a more powerful one.