en – Original Instructions
e-SHE, e-SHS
– Additional Installation, Operation and Maintenance Instructions 43
NOTICE:
If a motor other than the one supplied with the
pump unit
is used, check the maximum number
of starts shown in the motor manual.
8.5 Protection class
IP 55.
8.6 Electrical specifications
See the motor data plate.
Permitted tolerances for the supply voltage
No. of conductors + earth
230/400 ± 10, 400/690 ± 10
220/380 ± 5, 380/660 ± 10
8.7 Sound pressure
Measured in free field at a distance of one metre from the unit, with standard motor operating
without load.
50 Hz, 2-pole, @2900 min
-1
motors
≤ 70 dB except:
50-250/150, 65-200/150, 80-160/150, 40-250/150
50-250/220, 80-160/185, 65-200/220, 80-200/220
50 Hz, 4-pole, @1450 min
-1
motors
≤ 70 dB.
8.8 Materials in contact with the liquid
Pressed stainless steel 1.4404 (AISI 316L)
Pressed stainless steel 1.4404 (AISI 316L)
Pressed stainless steel 1.4404 (AISI 316L)
Cast stainless steel 1.4408 (cast AISI 316)
8.9 Mechanical seal
Unbalanced single acc. EN 12756, version K.