en – Original Instructions
e-SHE, e-SHS
– Additional Installation, Operation and Maintenance Instructions 39
8.2 Liquid temperature and maximum operating pressure
The diagram shows the maximum operating pressure based on unit model and temperature of
pumped liquid.
Minimum pressure required on the mechanical seal with hot water: it may be different with other liquids
P
1max
+ P
max
≤ PN
Maximum pressure generated by the unit
Maximum operating pressure
NOTE: The formula applies to units with motor with axially locked bearing on the drive side
(standard Xylem).
ESH_M0015_A_ot
-40
(-40)
-20
(-4)
0
(32)
20
(68)
40
(104)
60
(140)
80
(176)
100
(212)
120
(248)
140
(284)
0
(0,0)
5
(0,5)
10
(1,0)
15
(1,5)
20
(2,0)
PN [bar (MPa)]
t [°C (°F)]
EPDM
FKM
SS, SN
FKM (*)
(**)
EPDM, FKM
VBEGG
VBVGG
Q1BEGG
Q1BVGG
Q1Q1EGG
Q1Q1VGG