4.6.3.1
Spindle Control Module LED Segments
1
st
10 LED Segment
1. LED labeled GEAR 4 – not used.
2. LED labeled GEAR 3 – not used.
3. LED labeled GEAR 2 –The 1630 does not have a gear switch.
4. LED labeled GEAR 1 This light should be off when it is in high gear or
neutral. This light is not on for the 1630 because it has no gears.
5. LED labeled SPD-FAULT – this light will be on whenever the AC drive is in a
fault condition, which includes an E-stop message from the pendant.
6. LED labeled SPD-RUN – this light should be on whenever the spindle is on.
7. LED labeled SPD-ENABLE – this light should be on whenever you are in DRO,
tool setup and RUN mode.
8. LED labeled LUBE PUMP – this light should be on whenever the lube pump is
on and off when it is not on.
LED’s 9 and 10 are not used.
2
nd
10 LED Segment
1. LED labeled E-STOP OUT – this light should be on whenever the E-stop is in
the out position. When the E-stop is pressed, this light should go off.
2. LED labeled OFF RELAY – this light should be on whenever the off button on
the pendant is pressed.
3. LED labeled TAP MODE – light should be on whenever you are not tapping.
Light will be off when in the tap event.
4. LED labeled TAP REVERSE – this light will be on when the spindle changes
direction at the bottom of the hole on a tap event and back off after the
spindle changes direction once outside of the tap event.
5. LED labeled REV-RELAY – this light should be on whenever the spindle is
running in reverse.
6. LED labeled FWD-RELAY – this light should be on whenever the spindle is
running in forward.
7. LED labeled LI-BIT 1 – this LED should be on whenever the lathe indexer is
at any odd tool position.
8. LED labeled LI-BIT 2 – this LED should be on whenever the lathe indexer is
at tool positions 2, 3, 6 or 7.
LED’s 9 and 10 are not used.
3
rd
10 LED Segment
1. LED labeled LI-BIT 3 – this LED should be on whenever the lathe indexer is
at tool positions 4, 5, 6 or 7. For the 4 tool indexer, if you program tools 5,
6, 7 or 8, the indexer will physically move to tools 1, 2, 3 or 4 respectively.
For example, if you program tool 7, LED light LI BIT 3 should be on.
2. LED labeled LI-BIT 4 – this LED should be on whenever the lathe indexer is
at tool position 8.
3. LED labeled REMOTE E-STOP – this LED should be on whenever the remote
e-stop or pendant e-stop is in the out position.
4. LED labeled OIL PRESSURE – not used.