EasyManuals Logo

YASKAWA CACR-SR10BB User Manual

YASKAWA CACR-SR10BB
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
D 12.2 SERVOPACK
12.2.1 LED Indication (7-segment) for Troubleshooting
Table 12.2 LED Indication for Troubleshooting
LED Detection Lighting Condition Probable Cause Corrective Action
Goes ON when power issupplied to the Defective control circuit board Replace the SERVOPACK.
control circuit. (1 PWB).
Goes ON when power issupplied to the ° Defective current feedback circuit. Replace the SERVOPACK.
main circuit and servo power is turned Defective main circuit transistor Correct grounding.
ON. module.
MCCB does not trip. Motor grounding
[_] Over- Goes ON when power is supplied to the Defective motor grounding Replace the motor.
current main circuit and servo power is turned Defective main circuit transistor Replace the SERVOPACK.
ON. module.
MCCB does not trip.
Goes ON when power is supplied to the Defective main circuit transistor Replace the SERVOPACK.
main circuit, module.
Goes ON when the motor accelerates ,'Incomplete (1 PWB) VR8 Replace the SERVOPACK.
or decelerates. - adjustment.
Goes ON when power is supplied to the Defective control circuit board Replace the SERVOPACK.
control circuit. (1 PWB).
Circuit
-_ Goes ON when power is supplied to the * Defective main circuit thyristor- Replace the SERVOPACK.
protector
main circuit, diode module.
tripped MCCBtrips. '.
Defective main circuit of SERVOPACK
Goes ON during operation. (Do not turn ON again.)
D . .. Goes ON when power is supplied to the Defective control circuit board. Replace the SERVOPACK.
Regener- control circuit. (1 PWB).
_] ative Goes ON approximate 0.5 to 1 second Defective regenerative transistor. Replace the SERVOPACK.
after power is supplied to the main
trouble circuit. Regenerative resistor disconnection. Check and replace the regenerative
No regenerative resistor resistor. (Replace the SERVOPACK.
connection (SR60BB) -
Goes ON when the motor accelerates Load inertia JL (GD 2) is too large. Check the inertia of the machine
Over- or decelerates, with the value converted to the
r__ motorShaft.
voltage
Defective regenerative circuit. Replace the SERVOPACK.
D "
When the reference is input, the motor Motor connection error. ° Correct the motor connection.
Over- runs fast and [] goes ON. . Optical encoder connectior_ error. Check pulses in phases A, B, C, U,
-_ VandWon2CN,andcorrectwiring.
speed
The reference input voltage is too Decrease the reference input
large, voltage.
[_ Voltage Goes ON when power is supplied to the Defective main circuit thyristor- Replace the SERVOPACK.
drop main circuit. " diode module.
Goes ON when power is supplied to the Defective control circuit board Replace the SERVOPACK.
control circuit. (1 PWB).
Goes ON during operation. Operation with 105% to 130% or Check and correct the load
Overload When power to the control circuit is more of the rated load. (may be overload).
turned OFF and then ON again, the
operation starts.
Goes ON during operation. Fan has stopped. Check the fan.
When power to the control circuit is (SR20, 30, 44, 60)
turned OFF and then ON again,
I _] and [] goes ON again. Temperature around the Decrease the temperature below
Heat When reset later, the operation SERVOPACK exceeds 551C. 55°C (The heat sink may be
starts, overheated.)
[_] sink
D " overheat The motor rotates, but the torque is un- Motor circuit error connection, Correct the connection.
available. When power to the control such as U--*V, V_W, W-.U or
circuit is turned OFF and then ON again, single-phase connection.
the operation starts, but the torque is still
unavailable. .
-77-