xiii
Run Command ...........................................................................................6-15
îš‹
Selecting the Run Command Source ...........................................................................6-15
Stopping Methods.......................................................................................6-17
îš‹
Selecting the Stopping Method when a Stop Command is Sent...................................6-17
îš‹ Using the DC Injection Brake........................................................................................6-22
îš‹ Using an Emergency Stop ............................................................................................6-24
Acceleration and Deceleration Characteristics...........................................6-25
îš‹
Setting Acceleration and Deceleration Times...............................................................6-25
îš‹ Accelerating and Decelerating Heavy Loads (Dwell Function).....................................6-29
îš‹ Preventing the Motor from Stalling During Acceleration
(Stall Prevention During Acceleration Function) ...........................................................6-30
îš‹ Preventing Overvoltage During Deceleration
(Stall Prevention During Deceleration Function)...........................................................6-32
îš‹ Preventing Overvoltage by Automatically Reducing the Regenerative Torque Limit
(Overvoltage Inhibit Function, SPEC: E or later only)...................................................6-33
Adjusting Frequency References ...............................................................6-35
îš‹
Adjusting Analog Frequency References .....................................................................6-35
îš‹ Operation Avoiding Resonance (Jump Frequency Function) .......................................6-38
îš‹ Adjusting Frequency Reference Using Pulse Train Inputs ...........................................6-40
Speed Limit (Frequency Reference Limit Function) ...................................6-41
îš‹
Limiting Maximum Output Frequency ...........................................................................6-41
îš‹ Limiting Minimum Frequency........................................................................................6-41
Improved Operating Efficiency ...................................................................6-43
îš‹
Reducing Motor Speed Fluctuation (Slip Compensation Function) ..............................6-43
îš‹ Compensating for Insufficient Torque at Startup and Low-speed Operation
(Torque Compensation) ................................................................................................6-45
îš‹ Hunting-prevention Function.........................................................................................6-47
îš‹ Stabilizing Speed (Speed Feedback Detection Function) ............................................6-48
Machine Protection.....................................................................................6-49
îš‹
Limiting Motor Torque (Torque Limit Function) .............................................................6-49
îš‹ Preventing Motor Stalling During Operation .................................................................6-52
îš‹ Changing Stall Prevention Level during Operation Using an Analog Input ..................6-53
îš‹ Using Frequency Detection ..........................................................................................6-53
îš‹ Detecting Motor Torque ................................................................................................6-56
îš‹ Changing Overtorque and Undertorque Detection Levels Using an Analog Input .......6-59
îš‹ Motor Overload Protection............................................................................................6-60
îš‹ Setting Motor Protection Operation Time......................................................................6-62
îš‹ Motor Overheating Protection Using PTC Thermistor Inputs........................................6-63
îš‹ Limiting Motor Rotation Direction..................................................................................6-65
Continuing Operation..................................................................................6-66
îš‹
Restarting Automatically After Power Is Restored........................................................6-66
îš‹ Speed Search ...............................................................................................................6-67
îš‹ Continuing Operation at Constant Speed When Frequency Reference Is Lost............6-74
îš‹ Restarting Operation After Transient Fault (Auto Restart Function).............................6-75
îš‹ Operation Selection After Cooling Fan Fault (SPEC: E or Later Only).........................6-76