Motor Application Precautions
10-9
10
Motor Application Precautions
This section provides precautions for motor application.
îš‹ Using the Inverter for an Existing Standard Motor
When a standard motor is operated with the Inverter, power loss is slightly higher than when operated with a
commercial power supply. Observe the following precautions when using an Inverter for an existing standard
motor.
Low Speed Ranges
Cooling effects diminish in the low-speed range, resulting in an increase in the motor temperature. Therefore,
the motor torque should be reduced in the low-speed range whenever using a motor not made by Yaskawa. If
100% torque is required continuously at low speed, consider using a special Inverter or vector motor.
Installation Withstand Voltage
If the input voltage is higher than the motor rated voltage (440 V or higher) or the wiring distance is long, the
motor insulation voltage must be considered. Contact your Yaskawa representative for details.
High-speed Operation
When using the motor at a speed higher than the rated speed, problems may arise in dynamic balance and
bearing durability. Contact your Yaskawa representative for details.
Torque Characteristics
The motor may require more acceleration torque when the motor is operated with the Inverter than when oper-
ated with a commercial power supply. Check the load torque characteristics of the machine to be used with the
motor to set a proper V/f pattern.
Vibration
The Inverter uses a high carrier PWM to reduce motor vibration. (A constant can be set to select low carrier,
PWM modulation control as well.) The factory setting of the Inverter with SPEC: C or earlier is for a high car-
rier PWM and the one with SPEC: E or later is for a low carrier PWM. When the motor is operated with the
Inverter that uses a high carrier PWM, motor vibration is almost the same as when operated with a commercial
power supply.
Motor vibration may, however, become greater in the following cases.
Resonance with the Natural Frequency of the Mechanical System
Take special care when a machine that has been operated at a constant speed is to be operated in variable speed
mode. If resonance occurs, install vibration-proof rubber on the motor base or use the frequency jump function
to skip any frequency resonating the machine.
Imbalanced Rotor
Take special care when the motor is operated at a speed higher than the rated speed.