Interconnection Diagram
2-Wire ControlSection 7
After wiring is complete, verify that all wiring is correctly installed, excess screws and wire clip-
pings are removed from inside of unit, screws are securely tightened, and exposed wire does not
contact other wiring or terminals.
The Drive leaves the factory with all parameters set for 2-wire external control/ reference control.
To use the Drive in a 3-wire application, Drive parameters n001, n003 and n004 must be repro-
grammed and Figure 1-6 used for all external connections.
If a FWD or REV run command is given from the control circuit terminal when the operation
method selection function ( n003 ) is set to “ 1 ” and the “LO/RE” selection is set to “RE”, the
motor will start automatically as soon as power is applied to the main circuit.
CAUTION