Drive Parameter Listing
(n152-n163) Section 8
PARA- SETTING RANGE SETTING FACTORY USER PARA.
METER NAME (AND UNITS) INCREMENT SETTING SETTING REF.
0: 0.1 Hz
n152
Modbus Frequency 1: 0.01 Hz
Reference Unit 2: 30000/100%
10
3: 0.1 %
n153 Modbus Slave Address 0 to 32 1 0
0: 2400 bps
n154 Modbus Baud Rate
1: 4800 bps 5.14
2: 9600 bps
12
3: 19200 bps
0: even parity
n155 Modbus Parity Selection 1: odd parity 1 2
2: no parity
n156 Modbus Send Waiting Time 10 to 65 1 (msec) 10
0: RTS control enabled
n157 Modbus RTS control 1: RTS control disabled 1 0
(RS-422A 1 to 1 communication)
n158 Motor Code 0 to 70 1 (Note 1)
n159
Energy Saving Voltage
Upper Limit At 60 Hz 0 to 120 1% 120
(Energy Saving)
n160
Energy Saving Voltage
Upper Limit At 6 Hz 0 to 25 1% 16
(Energy Saving) 5.31
5.28
n161
Power Supply Detection
0 to 100 1% 10
Hold Width (Energy Saving)
n162
Power Supply Detection
0 to 255
15
Filter Time Constant (x 4 ms) (20 ms)
n163 PID Output Gain 0.0 to 25.0 0.1 1.0
Drive Parameters - Continued