3 Utility Function Mode
3.2.15 Write Prohibited Setting (Fn010)
3-38
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Note: To make the setting available, change the setting to P.0000 as shown in step 3.
Step Display after Operation Keys Operation
1
Press the Key to view the main
menu for the utility function mode.
Use the
or Key to move
through the list and select Fn010.
2
Press the
Key. The display
changes to the Fn010 execution dis-
play.
3
Press the
or Key to
select one of the following settings.
P.0000: Write permitted [Factory set-
ting]
P.0001: Write prohibited
4
Press the
Key. The setting value
is written into the SERVOPACK, and
the status display changes as follows:
“DONE” to “BB.”
Note: Saved settings will be enabled
after the SERVOPACK is
restarted.
5 Turn OFF the power and then turn it ON again to validate the new setting.
BB
FUNCTION
Fn00F:Cur ManuAdj
Fn010:Prm Protect
Fn011 :Motor Info
Fn012:Soft Ver
BB
Parameter
Write Protect
P. 0000
BB
Parameter
Write Protect
P. 0001
BB
Parameter
Write Protect
P. 0001

Table of Contents

Other manuals for YASKAWA E-7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-7 Series and is the answer not in the manual?

YASKAWA E-7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-7 Series
CategoryServo Drives
LanguageEnglish

Related product manuals