| Protection Class | IP20 |
|---|---|
| Rated Output Power | 0.1-15 kW |
| Output Power | 0.05 kW to 15 kW (depending on model) |
| Output Current | Varies by model |
| Rated Speed | Varies by model |
| Communication Interface | MECHATROLINK-II, MECHATROLINK-III, EtherCAT |
| Protection | Overvoltage, Undervoltage, Overheating |
| Encoder | Incremental encoder, Absolute encoder |
| Protection Features | Overcurrent, Overvoltage, Undervoltage, Overheating, Encoder error |
| Ambient Temperature | 0°C to +55°C |
| Storage Temperature | -20°C |
| Vibration Resistance | 5.9 m/s2 |
Details electrical ratings, specifications, and control modes for SERVOPACKs.
Guides on how to set parameters using the panel operator.
Covers wiring of main circuit terminals, wire size, and examples.
Explains I/O signals, terminal layouts, and connection examples.
Lists essential checks for servomotors and SERVOPACKs before trial operation.
Details procedures for trial operation using host references without a load.
Describes trial operation procedures after connecting the servomotor to the machine.
Describes the supported control modes and how to select them via parameter Pn000.
Details operations for speed control using analog voltage references.
Details operations for position control using pulse train references.
Details operations for torque control using analog voltage references.
Incorporates safety functions to reduce risks and ensure safe machine operation.
Covers servo gain adjustments and basic procedures for optimizing responsiveness.
Enables stable response adjustment without regard to machine type or load changes.
Automatically adjusts parameters based on set speed loop gain during operation.
Automatically tunes SERVOPACK optimally based on user reference inputs.
Allows manual tuning of servo gain settings during operation.
Allows checking the status of input signals using the input signal monitor (Un005).
Allows checking the status of output signals using the input signal monitor (Un006).
Describes system configuration and connection examples for fully-closed loop control.
Outlines the necessary settings for implementing fully-closed loop control.
Provides guidance for troubleshooting common alarm displays.
Provides guidance for troubleshooting warning displays.
Addresses malfunctions based on servomotor operation and conditions.
Lists available parameters for SERVOPACK configuration.