EasyManua.ls Logo

YASKAWA SGMPS - 8.5 Monitoring Safety Input Signals

YASKAWA SGMPS
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.5 Monitoring Safety Input Signals
8-7
8
Monitor Modes (Un)
8.5 Monitoring Safety Input Signals
The status of safety input signals can be checked with the safety I/O signal monitor (Un015). How to read the
displayed safety input signal status and a display example are shown below.
8.5.1 Interpreting Safety Input Signal Display Status
The status of allocated signals is displayed on the 7-segment display on the Panel Operator.
Input terminals correspond to LED numbers as shown in the following table.
When the safety input signal is OFF (open) status, the top segment (LED) is lit.
When the safety input signal is ON (short-circuited) status, the bottom segment (LED) is lit.
8.5.2 Safety Input Signal Display Example
A display example of safety input signal status is shown below.
When /HWBB1 signal turns OFF to activate the HWBB function.
Display LED Number Input Terminal Name
Signal Name
(Factory Setting)
1 CN8-3, -4 /HWBB1
2 CN8-5, -6 /HWBB2
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
4321675
8
Top: OFF (H level)
Bottom: ON (L level)
Number
The top segment of
the number 1 is lit.
76543218