EasyManua.ls Logo

YASKAWA SGMPS - Speed;Position;Torque Control Modes

YASKAWA SGMPS
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Outline
1.3.3 Speed/Position/Torque Control Modes
1-6
1.3.3 Speed/Position/Torque Control Modes
The following table shows the basic specifications at speed/position/torque control mode.
Control Mode Specifications
Speed Control
Performance Soft Start Time Setting
0 to 10 s (Can be set individually for acceleration and
deceleration.)
Input
Signals
Reference Voltage
Max. input voltage: ±12 V
(forward speed reference with positive reference)
Factory setting: 6 VDC at rated speed
Input gain setting can be varied.
Input Impedance About 14 kΩ minimum
Circuit Time Constant 30 μs
Internal Set
Speed Control
Rotation Direction
Selection
With P control signal
Speed Selection
With forward/reverse torque limit signal (speed 1 to 3
selection), servomotor stops or another control method is
used when both are OFF.
Position Control
Performance
Feedforward
Compensation
0 to 100% (setting resolution: 1%)
Positioning
Completed Width
Setting
0 to 1073741824 reference units (setting resolution: 1 ref-
erence unit)
Input
Signals
Refer-
ence
Pulse
Type
Sign + pulse train, 90° phase difference 2-phase pulse
(phase A + phase B), or CW + CCW pulse train
Form For line driver, open collector
Max. Input
Pulse
Frequency
Line driver
Sign + pulse train, CW + CCW phase train: 4 Mpps
90° phase difference 2-phase pulse: 1 Mpps
Open Collector
Sign + pulse train, CW + CCW phase train: 200 kpps
90° phase difference 2-phase pulse: 200 kpps
Clear Signal
Error pulse clear
For line driver, open collector
Torque Control
Input
Signals
Reference Voltage
Max. input voltage: ±12 V
(forward torque reference with positive reference)
Factory setting: 3 VDC at rated torque
Input gain setting can be varied.
Input Impedance About 14 kΩ minimum
Circuit Time Constant
16 μs

Table of Contents

Related product manuals