5.2.2 Servomotor Rotation Direction
The servomotor rotation direction can be reversed with parameter Pn000 without changing the polarity of the
speed/position reference.
This causes the travel direction of the motor change, but the encoder pulse output polarity does not change.
∗ The standard setting for “forward rotation” is counterclockwise (CCW) as viewed from the drive end.
Parameter Meaning
Signal for
Overtravel
Pn000
n.
0
Standard setting
(Forward reference
= forward rotation)
[Factory setting]
Forward Reference
Trace Waveform of Un Monitor or SigmaWin+
At forward rotation:
Uses the P-OT
signal.
Reverse Reference
Trace Waveform of Un Monitor or SigmaWin+
At reverse rotation:
Uses the N-OT
signal.
n.
1
Reverse Rotation Mode
(Forward reference
= reverse rotation)
Forward Reference
Trace Waveform of Un Monitor or SigmaWin+
At reverse rotation:
Uses the P-OT
signal.
Reverse Reference
Trace Waveform of Un Monitor or SigmaWin+
At forward rotation:
Uses the N-OT
signal.