EasyManua.ls Logo

YASKAWA GA500 series - Page 231

YASKAWA GA500 series
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network Communications
6
6.3 MEMOBUS/Modbus Communications
YASKAWA SIEPC71061753C GA500 Technical Manual 231
Register No.
(Hex.)
Description
000F
Command selection setting
bit 0 Reserved
bit 1
Input for the PID setpoint
1: Enables target values from MEMOBUS/Modbus
bit 2
Torque Limit Input
1: Enables setting values from MEMOBUS/Modbus
bit 3
Torque Compensation Input
1: Enables setting values from MEMOBUS/Modbus
bit 4 Reserved
bit 5
PID feedback from the MEMOBUS/Modbus
1: Enables PID feedback (15FF (Hex.)) from MEMOBUS/Modbus
bit 6 - B Reserved
bit C
Terminal S5 input of broadcast message
1: Enabled, 0: Disabled
bit D
Terminal S6 input of broadcast message
1: Enabled, 0: Disabled
bit E
Terminal S7 input of broadcast message
1: Enabled, 0: Disabled
bit F Reserved
0010 - 001F Reserved
15C0
bit 0
Extended multi-function input command 1
bit 1
Extended multi-function input command 2
bit 2
Extended multi-function input command 3
bit 3 - F Reserved
3004
Time Setting
Setting range: 0000 to 2359 (decimal), the default value at energize: 0000
Set the hour and the minute in HHMM format.
HH: 00 to 23 (decimal)
MM: 00 to 59 (decimal)
3005
Year and Day Setting
Setting range: 1600 to 9906 (decimal), the default value at energize: 1600
Set the year and the day of the week in YYDW format.
YY: the last two digits of the year from 16 to 99 (decimal)
DW: the day of the week
Sunday: 00
Monday: 01
Tuesday: 02
Wednesday: 03
Thursday: 04
Friday: 05
Saturday: 06
3006
Date Setting
Setting range: 101 to 1231 (decimal), the default value at energize: 101
Set the month and the date in MMDD format.
MM: 01 to 12 (decimal)
DD: 01 to 31 (decimal)
3007
Set the Date Information
Setting range: 0 to 8 (decimal), the default value at energize: 8
Set the values specified in 3004H to 3006H as the date and time.
Command Data: 1
Response Data: 0 (normal), 8 (fault)
Monitor Data
You can only read monitor data.

Table of Contents

Other manuals for YASKAWA GA500 series

Related product manuals