EasyManua.ls Logo

YASKAWA GA500 series - B8: Energy Saving

YASKAWA GA500 series
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.5 b: Application
370 YASKAWA SIEPC71061753C GA500 Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
b6-03
(01B8)
Dwell Reference at Stop
Sets the output frequency that the drive will hold momentarily when ramping to stop the
motor.
0.0
(Determined by A1-02)
541
b6-04
(01B9)
Dwell Time at Stop
Sets the length of time for the drive to hold the output frequency when ramping to stop
the motor.
0.0 s
(0.0 - 10.0 s)
541
b8: Energy Saving
No.
(Hex.)
Name Description
Default
(Range)
Ref.
b8-01
(01CC)
Energy Saving Control
Selection
Sets the Energy-saving control function.
0 : Disabled
1 : Enabled
2 : Automatic Optimization
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], you can only select
setting 2 in Expert Mode.
0
(0 - 2)
542
b8-02
(01CD)
RUN
Expert
Energy Saving Gain
Sets the gain for Energy-saving control.
Determined by A1-02
(0.0 - 10.0)
542
b8-03
(01CE)
RUN
Expert
Energy Saving Filter
Time
Sets the responsiveness for Energy-saving control.
Determined by A1-02
C6-01 and o2-04
(0.00 - 10.00 s)
542
b8-04
(01CF)
Expert
Energy Saving
Coefficient Value
Sets the Energy-saving control coefficient to maintain maximum motor efficiency. The
default setting is for Yaskawa motors.
Determined by C6-01,
E2-11, and o2-04
(0.00 - 655.00)
542
b8-05
(01D0)
Expert
Power Detection Filter
Time
Sets the time constant to measure output power.
20 ms
(0 - 2000 ms)
542
b8-06
(01D1)
Expert
Search Operation
Voltage Limit
Sets the voltage limit for Search Operation as a percentage of the motor rated voltage.
0%
(0 - 100%)
543
b8-16
(01F8)
Expert
PM E-Save Coefficient
Ki
Sets torque linearity. This parameter uses the Ki value from the motor nameplate.
Usually it is not necessary to change this setting.
1.00
(0.00 - 3.00)
543
b8-17
(01F9)
Expert
PM E-Save Coefficient
Kt
Sets torque linearity. This parameter uses the Kt value from the motor nameplate.
Usually it is not necessary to change this setting.
1.00
(0.00 - 3.00)
543
b8-18
(01FA)
Expert
E-Save d-axis Current
FilterTime
Sets the d-axis current reference filter time constant.
0.100 s
(0.000 - 5.000 s)
543
b8-19
(0B40)
Expert
E-Save Search
Frequency
Sets the frequency of Energy-saving control search operations. Usually it is not
necessary to change this setting.
Determined by A1-02
(10 - 300 Hz)
543
b8-20
(0B41)
Expert
E-Save Search Width
Sets the amplitude of Energy-saving control search operations.
1.0 degrees
(0.1 - 5.0 degrees)
544
b8-21
(0B42)
Expert
PM E-Save Search Gain
Sets the gain of Energy-saving control search operations.
0.3Hz
(0.1 - 20.0 Hz)
544
b8-22
(0B43)
Expert
PM E-Save Search LPF
Cutoff Freq
Sets the frequency of the filter used to extract the high-efficiency phase from search
operations. Usually it is not necessary to change this setting.
10.0 Hz
(1.0 - 30.0 Hz)
544
b8-23
(0B44)
Expert
PM E-Save Search Limit
Sets the search operations output limit. Usually it is not necessary to change this setting.
15.0 degrees
(0.0 - 30.0 degrees)
544
b8-24
(0B45)
Expert
PM E-Save High Freq
ACR Gain
Sets the gain for high-frequency current control.
200.0 Hz
(100.0 - 1000.0 Hz)
544
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents