12.9 L: Protection Functions
736 YASKAWA SIEPC71061753C GA500 Technical Manual
L8-94: Low Speed Pull-out Detect Level
No.
(Hex.)
Name Description
Default
(Range)
L8-94
(073D)
Expert
Low Speed Pull-out Detect
Level
Sets the detection level for LSo [Low Speed Motor Step-Out] as a percentage of E1-04 [Maximum
Output Frequency].
3%
(0 - 10%)
L8-95: Low Speed Pull-out Amount
No.
(Hex.)
Name Description
Default
(Range)
L8-95
(077F)
Expert
Low Speed Pull-out
Amount
Sets the average count of LSo [Low Speed Motor Step-Out] detections.
10
(1 - 50 times)
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV