3 Drive Specifications
12 YASKAWA TOEPC71061752B GA500 Drive Installation & Primary Operation
Item Specification
Starting Torque
V/f: 150%/3 Hz
OLV: 150%/1 Hz
OLV/PM: 100%/5% speed
AOLV/PM: 100%/0 min
-1
(when high frequency injection is enabled)
EZOLV: 100%/10% speed
Note:
Correctly select the drive and motor capacity for this starting torque in these control methods:
OLV
AOLV/PM
Speed Control
Range
V/f: 1:40
OLV: 1:100
OLV/PM: 1:10
AOLV/PM: 1:100 (when high frequency injection is enabled)
EZOLV: 1:10
Zero Speed
Control
Possible in AOLV/PM control methods.
Torque Limits
You can use parameter settings for different limits in four quadrants in these control methods:
OLV
AOLV/PM
EZOLV
Acceleration and
Deceleration
Times
0.0 s to 6000.0 s
The drive can set four pairs of different acceleration and deceleration times.
Braking Torque
Approximately 20% without a resistor
Approximately 125% with a dynamic braking option
WARNING
Set L3-04 = 0 [Stall Prevention during Decel = Disabled] when you
operate the drive with:
a regenerative converter
regenerative unit
braking resistor
braking resistor unit.
If you set the parameter incorrectly, the drive can decelerate for too long and cause serious
injury or death.
Note:
Short-time average deceleration torque refers to the torque needed to decelerate the motor
(uncoupled from the load) from the rated speed to zero. Motor characteristics can change the
actual specifications.
Motor characteristics change the continuous regenerative torque and short-time average
deceleration torque for motors 2.2 kW and larger.
V/f
Characteristics
Select from 15 pre-defined V/f patterns, or a user-set V/f pattern.
Main Control
Functions
Feed Forward Control, Restart After Momentary Power Loss, Speed Search, Overtorque Detection,
Torque Limit, 17 Step Speed (max.), Accel/Decel Switch, S-curve Acceleration/Deceleration, 3-wire
Sequence, Auto-Tuning (Rotational and Stationary), Dwell Function, Cooling Fan ON/OFF Switch,
Slip Compensation, Torque Compensation, Frequency Jump, Upper/Lower Limits for Frequency
Reference, DC Injection Braking at Start and Stop, Overexcitation Braking, High Slip Braking, PID
Control (with Sleep Function), Energy Saving Control, MEMOBUS/Modbus Communications (RS-
485 max, 115.2 kbps), Auto Restart, Application Presets, DriveWorksEZ (customized functions),
Parameter Backup Function, Online Tuning, KEB, Overexcitation Deceleration, Overvoltage
Suppression, High Frequency Injection, etc.