EasyManua.ls Logo

YASKAWA GA50U Series

YASKAWA GA50U Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Receiving
YASKAWA TOEPC71061752B GA500 Drive Installation & Primary Operation 15
Figure 5.2 Drive Catalog Code
Table 5.1 Catalog Code Details
No. Description
1 Product series
2 Region code
A: Japan
B: China
C: Europe
T: Asia (Singapore, Taiwan, India, and Korea)
U: Americas
3 Input power supply voltage
B: Single-Phase AC 200 V Class
2: Three-Phase AC 200 V Class
4: Three-Phase AC 400 V Class
4 Rated output current
Note:
Refer to Table 5.2, Table 5.3, and Table 5.4 for the rated output current by model.
5
EMC noise filter
A: No internal EMC filter
E: Built-in EMC Filter
6 Enclosure protection design
B: IP20/UL Open Type
7 Environmental specification
A: Standard
Rated Output Current
Table 5.2, Table 5.3, and Table 5.4 give the rated output current values.
Note:
Rated output current values are applicable for drives that operate at standard specifications.
Derate the output current in applications that:
Increase the carrier frequency
Have high ambient temperature
Install drives side-by-side
Use C6-01 [Normal / Heavy Duty Selection] to select Normal Duty rating (ND) or Heavy Duty rating (HD).

Table of Contents