5 Receiving
16 YASKAWA TOEPC71061752B GA500 Drive Installation & Primary Operation
Table 5.2 Single-Phase AC 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
B001 0.1 (1/6) 0.8 0.2 (1/6) 1.2
B002 0.2 (1/4) 1.6 0.4 (1/4) 1.9
B004 0.4 (1/2) 3.0 0.75 (3/4) 3.5
B006 0.75 (1) 5.0 1.1 (1.5) 6.0
B010 1.5 (2) 8.0 2.2 (3) 9.6
B012 2.2 (3) 11.0 3.0 (3) 12.2
B018 3.7 (5) 17.6 - -
Table 5.3 Three-Phase AC 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
2001 0.1 (1/6) 0.8 0.2 (1/6) 1.2
2002 0.2 (1/4) 1.6 0.4 (1/4) 1.9
2004 0.4 (1/2) 3.0 0.75 (3/4) 3.5
2006 0.75 (1) 5.0 1.1 (1.5) 6.0
2010 1.5 (2) 8.0 2.2 (3) 9.6
2012 2.2 (3) 11.0 3.0 (4) 12.2
2021 3.7 (5) 17.6 5.5 (5) 21.0
2030 5.5 (7.5) 25.0 7.5 (10) 30.0
2042 7.5 (10) 33.0 11.0 (15) 42.0
2056 11.0 (15) 47.0 15.0 (20) 56.0
2070 15.0 (20) 60.0 18.5 (25) 70.0
2082 18.5 (25) 75.0 22.0 (30) 82.0

Table of Contents