Setting Function Page
8 During baseblock (N.O.) –
9 Frequency reference source –
A Run command source –
A HAND Mode –
B Torque detection 1 (N.O.) –
C Frequency reference loss –
D
<1>
Braking resistor fault –
E Fault –
F Through mode –
10 Minor fault –
11 Fault reset command active –
12 Timer output –
13 Speed agree 2 –
14 User-set speed agree 2 –
15 Frequency detection 3 –
16 Frequency detection 4 –
17 Torque detection 1 (N.C.)
–
18 Torque detection 2 (N.O.)
19 Torque detection 2 (N.C.) –
1A During reverse –
1B During baseblock (N.C.) –
1E Restart enabled –
1F Motor overload alarm (oL1) –
20 Drive overheat pre-alarm (oH) –
22 Mechanical weakening detection –
2F Maintenance period –
30 During torque limit 61
37 During frequency output –
38 Drive enabled –
39 Watt hour pulse output –
3D During speed search –
3E PID feedback low –
3F PID feedback high –
40 Auto Mode –
42 Pressure Reached 61
43 2 Motor Alternate –
4A During KEB Ride-Thru –
4C During fast stop –
4D oH Pre-alarm time limit –
4E
<2>
Braking transistor fault (rr) –
4F
<2>
Braking resistor overheat (oH) –
51 Sequence timer 1 –
Setting Function Page
52 Sequence timer 2 –
53 Sequence timer 3 –
54 Sequence timer 4 –
58 Underload detection –
60 Internal cooling fan alarm –
71 Secondary PI Feedback Low –
72 Secondary PI Feedback High –
80 Pump 2 Control –
81 Pump 3 Control –
82 Pump 4 Control –
83 Pump 5 Control –
84 Pump 6 Control –
89 Output 1 Limit –
8B Lube Pump or Digital Output Delay –
8F Internal Fan On –
91 Pump Fault –
92 Transducer Loss –
93 Setptoint Not Met –
94 Loss of Prime –
95 Volute Thermostat Fault –
96 High Feedback –
97 Low Feedback –
98 Low Flow –
99 Accum Level –
9A High Flow –
9B Low Water Level –
9C Low Suction –
9D High Suction –
9E Low PI Aux Level –
9F High PI Aux Level –
A0 Water Loss/Suction Pressure/PI Aux Control –
A1 Differential Detected –
A2 Sleep Active –
A3 Start Delay –
A4 Pre-Charge –
A5 Anti-Jam Active –
A6 De-Scale Active –
A7 Flow Rate Limit
A9 Thrust Mode –
AA Utility Start Delay –
100 to
1AA
Function 0 to AA with inverse output –
<1> Not available in models 4A0930 and 4A1200.
<2> Not available in models 2A0169 to 2A0415 and 4A0088 to 4A1200.
Setting 30: During Torque Limit
The output closes when the motor is operating at the torque limit specified by the L7-oo parameters or an analog input. This
setting can only be used in OLV control mode.
Setting 42: Pressure Reached
Note: 1. Setting available in drive software versions PRG: 8552 and later.
2. Setting not available in drive models 4A0930 and 4A1200.
i.5 Start-Up Programming and Operation
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide
61