3 Equipment Description
3.5 Miller-Motoman Pendant Interface (HMI) Software
3-4
166465-1CD
166465-1CD
Auto-Axcess DI/E Digital
Fig. 3-3: Welcome Screen
1. Number of Welders: Enter the number of welders attached to the
system (1-4).
2. Manager Password: Factory Default is 99999999 (eight 9’s). Enter
the password (up to eight characters) for management rights.
3. Type password again: Re-enter the password to verify.
4. Select Welder Size: Specify the size of the welders being connected.
5. Comm Selection: Select the applicable digital interface being used for
welder communication.
6. Starting input address for first welder: (Only required if DeviceNet
communication is selected). In the case of DeviceNet communication
this textbox field specifies the starting input address of the DeviceNet
board (excluding the status bits). In most cases the default address of
00050 (input#33) is correct. However if an expanded I/O board is
used, this starting address may need to be adjusted.
7. Continue: When all the required fields above have been completed,
push continue to {Continue} or press {Cancel Setup} if wanting to
return to last settings.
1
2
3
4
5
6
7
NOTE
If other devices are added to the DX100 controller after the
original DeviceNet installation, the starting address, as well
as the ladder, may require changes.