5-1
166465-1CD
166465-1CD
Auto-Axcess DI/E Digital
5 Operation
5.1 Set-Up Overview
5 Operation
5.1 Set-Up Overview
This chapter covers set-up information that is unique to the DX100/Miller
Auto-Axcess system. It covers:
• Setting the Welder Condition File
• Arc Start Files and Arc End Files
• Verifying the welder calibration
• Selecting weld programs
5.1.1 Welder Condition File
The Welder Condition file is set as follows (this has been preset by
Yaskawa Motoman):
POWER SUPPLY: A/V
Table 5-1: Welder Output
<CURRENT OUTPUT
CHARS.>
<WELDING VOLTAGE OUTPUT>
RANGE ++
ADJUST 1.00 1.00
NO. REF. (V) MEASURE (A) REF. (V) MEASURE (V)
01 0.52 40 0.26 1.0
02 1.16 90 1.30 5.0
03 2.57 200 2.60 10.1
04 3.85 300 3.86 15.0
05 5.12 399 5.14 20.0
06 6.39 498 6.45 25.1
07 8.71 679 7.70 30.0
08 12.81 999 11.29 44.0
• Although the robot teach pendant displays “A”, “AC” or
“amps” in Arc Start Files, ARCON commands, etc., when
using the above calibration data, the values used are in
units of INCHES/MIN., NOT AMPERAGE, and correspond
to the actual WIRE FEED SPEED of the wire feeder.
• The Digital Interface uses direct settings, no special
procedures like AutoCal are required.