3-9
166465-1CD
166465-1CD
Auto-Axcess DI/E Digital
3 Equipment Description
3.5 Miller-Motoman Pendant Interface (HMI) Software
3.5.6 Live Weld Data Screen
The Live Weld Data screen (Fig. 3-7) displays Voltage, Current, Wire Feed
Speed (WFS), Travel Speed
1)
, and Heat Input
1)
. It also displays the status
(On/Off) of the wire feeder, gas solenoid, and weld contactor.
Fig. 3-7: Live Weld Data Screen
1. View data for: If more than one welder is connected to the system,
select the desired welder # to view its data.
2. Current Program: Displays the weld program (1-8) selected on the
Auto-Axcess DI/E Digital.
3. Volts: Actual welding voltage.
4. Amps: Actual welding Current, in Amps.
5. WFS: Actual welding Wire Feed Speed, in inches/minute.
6. TS (cm/min) (E Digital only): Travel Speed of the Robot's TCP.
7. Heat (J/cm) (E Digital only): Heat input calculated by the welder
based on the travel speed of the Robot's TCP.
8. Wire Feed: Red=Wire Feeder is Off. Green=running in either forward
(welding) or reverse (retracting wire).
1 Travel Speed and Heat Input are only shown on the E Digital interfaces. The DI
interface will not show these fields.
The Miller Auto-Axcess updates the program number.prior
to welding.
• Using the DI the program number being run is displayed
while the Arc is on.
• Using the E Digitial the specified program number
immediately shows and does not require an ArcOn.