Closed-Loop Crimp Terminal Recommendations
To maintain UL/cUL approval, UL Listed closed-loop crimp terminals are specifically required when wiring the drive main
circuit terminals on models 2A0110 to 2A0415, 4A0058 to 4A1200, and 5A0041 to 5A0242. Use only the tools recommended
by the terminal manufacturer for crimping. Yaskawa recommends crimp terminals made by JST and Tokyo DIP (or equivalent)
for the insulation cap. Table i.8 matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimp
terminals, tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge
and screw size for your drive model. Place orders with a Yaskawa representative or the Yaskawa sales department.
Wire gauge values shown in bold italic are the recommended values. Refer to local codes for proper selections.
Table i.8 Closed-Loop Crimp Terminal Size
Drive Model
Wire Gauge (AWG, kcmil)
Screw
Size
Crimp
Terminal
Model Number
Tool
Insulation Cap
Model No.
Code
<1>
R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 Machine No. Die Jaw
200 V Class
2A0004
2A0006
2A0008
2A0010
14
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
2A0012
14 14
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12 12
R5.5-4 TP-005 100-054-029
10
2A0018
– 14
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
2A0021
12
M4 R5.5-4 YA-4 AD-900 TP-005 100-054-029
10
2A0030
10
M4
R5.5-4
YA-4
AD-900 TP-005 100-054-029
8 8-4 AD-901 TP-008 100-054-031
6 14-NK4 AD-902 TP-014 100-054-033
2A0040
8 8
M4
8-4
YA-4
AD-901 TP-008 100-054-031
6 6 14-NK4 AD-902 TP-014 100-054-033
2A0056
6
M6
R14-6
YA-5
AD-952 TP-014 100-051-261
4 R22-6 AD-953 TP-022 100-051-262
2A0069
4
M8
R22-8
YA-5
AD-953 TP-022 100-051-263
3 R38-8 AD-954 TP-038 100-051-264
2A0081
3
M8 R38-8 YA-5 AD-954 TP-038 100-051-264
2
2A0110
3
M8
R38-8 YA-5 AD-954 TP-038 100-051-2642
1
1/0 R60-8 YA-5 AD-955 TP-060 100-051-265
2A0138
1
M10
R38-10
YF-1
YET-300-1
TD-321,
TD-311
TP-060
100-061-114
1/0 R60-10 100-051-266
2/0 70-10
TD-323,
TD-312
TP-080 100-054-036
2A0169
2/0 –
M10
70-10
YF-1
YET-300-1
TD-323,
TD-312
TP-080
100-054-036
3/0 80-10 100-051-267
4/0 R100-10
TD-324,
TD-312
TP-100 100-051-269
2A0211
1/0 × 2P
M10
R60-10
YF-1
YET-300-1
TD-321,
TD-311
TP-060 100-051-266
2/0 × 2P 70-10
TD-323,
TD-312
TP-080 100-054-036
i.3 Electrical Installation Safety
YASKAWA ELECTRIC TOEP YAIP1U 03B YASKAWA AC Drive – P1000 Safety Precautions
31