EasyManua.ls Logo

YASKAWA SGD7S-180A - Page 116

YASKAWA SGD7S-180A
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.3 Program Table Operation
7.3.7 Program Table Operation Examples
7-35
Combining Positioning with Constant-Speed Operation
This example shows how to perform operation that combines constant-speed operation and
positioning when the target position (POS) is set to INFINITE.
Step 0 performs operation for 2 seconds with no target position (infinite length = INFINITE) at a
speed of 15,000,000 reference units/min.
Step 1 performs operation with no target position (infinite length = INFINITE) and changes the
speed from 15,000,000 reference units/min to 30,000,000 reference units/min. Operation con-
tinues until the /SEL0 signal turns ON.
Step 2 decelerates the motor to a stop and step 3 performs relative positioning from the stop
position to a target position of 200,000 reference units.
Operating Procedure
Turn ON the /MODE 0/1 signal to change to mode 0.
Set the /SEL0 to /SEL4 signals to 0 to specify program step 0.
Turn ON the /START-STOP signal to start program table operation.
The /COIN signal turns OFF.
After 2 seconds elapse, step 1 is executed.
When the /SEL0 signal turns ON, step 2 is executed.
After the motor decelerates to a stop, the /COIN signal turns ON and step 3 is executed.
At the start of execution, the /COIN signal turns OFF.
When positioning is completed to the target position, the /COIN signal turns ON.
When the /SEL1 signal turns ON, program step 3 is ended and program step 0 is exe-
cuted.
Operation Pattern and Related Signal Timing
* Do not change /SEL0 to /SEL7 for 4 ms after turning ON the /START-STOP signal.
PGM-
STEP
POS SPD RDST RSPD ACC DEC POUT EVENT LOOP NEXT
0
+INFINITE
15000 - 1000 400000 200000 NNNNN T2000 1 1
1
+INFINITE
30000 - 1000 : : : SEL0T0 1 2
2
STOP
30000 - 1000 : : : IT0 1 3
3
I+200000
30000 - 1000 : : : SEL1T0 1 0
0121
START-STOP*
/COIN
/MODE 0/1
/SEL0 to
/SEL4*
1 ms min.
Operation
Pattern
1 ms min.
Speed
Time
Mode 0 (Program Table Operation)
Step 0
Step 1

2 s
Step 2
Step 3
Step 0
Step 1
Step 2
Step 3
2 s
1 ms min. 1 ms min. 1 ms min.

Table of Contents