No.
n.X
/SEL4 (Program Step Selection Input 4) Signal Allocation Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-3
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/JOGP (Forward Jog Input) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3
n.X
/JOGN (Reverse Jog Input) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3
n.X
/JOG0 (Jog Speed Table Selection Input 0) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3