EasyManua.ls Logo

YASKAWA SGD7S-180A - Page 237

YASKAWA SGD7S-180A
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2 List of Parameters
9.2.2 List of Parameters
9-37
Pn632
2
Input Signal Selections
12
0000h to
FFFFh
5438h All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
/SEL4 (Program Step Selection Input 4) Signal Allocation Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-3
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/JOGP (Forward Jog Input) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3
n.X
/JOGN (Reverse Jog Input) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3
n.X
/JOG0 (Jog Speed Table Selection Input 0) Signal Allocation Reference
0 to F
The settings are the same as for /SEL4 (Program Step Selection
Input 4) Signal Allocation.
page 6-3

Table of Contents