BASIC USES OF Σ-SERIES PRODUCTS
26
Connector kits for pulse generator (PG) and for
motor are not required if the following parts are
ordered:
S Cable with terminal connectors
S Cable with connector and amplifier terminal
Standard connection method for Σ-Series AC Servo Drives:
Molded-case circuit breaker (MCCB)
Used to protect power
supply line. Shuts the
circuit off when
overcurrent is detected.
Noise filter
Used to eliminate
external noise from
power supply line.
Types: LF-205A (for SGDA-A3A, A5B, 01A, 02A,
A3B, A5B, and 01B)
LF-210 (for SGDA-04A and 02B)
LF-220 (for SGDA-03B and 08A)
Magnetic contactor
Turns the servo ON or OFF.
Use a surge suppressor for
the magnetic contactor.
Type: HI-15E5 (30 A)
Brake power supply
Used for Servomotor with brake.
Types:
LPSE-2H01 (for 200 V input)
LPDE-1H01 (for 100 V input)
Regenerative unit
Type: JUSP-RG08
Digital
Allows the user to set user constants or
operation references and display operation
status or alarm status. The following two
types are available in addition to personal
computers:
Mount type (JUSP-OP03A)
This type can be mounted directly on
the Servopack.
Power supply:
Single-phase
200 or 100 V
This wiring is required
only for a Servomotor
with brake
Brake
control
relay
Σ-Series Servopack
Exterior type regenerative
resistor
Type: JUSP-RG08C
Connector for PG
(on Servopack side)
R
T
P
N
U
V
W

Table of Contents

Other manuals for YASKAWA SGM series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGM series and is the answer not in the manual?

YASKAWA SGM series Specifications

General IconGeneral
BrandYASKAWA
ModelSGM series
CategoryServo Drives
LanguageEnglish

Related product manuals