4. Wiring
27
200 V Class Single-phase Input Inverters
Note: 1. The wire size is given for copper wire at 75°C.
2. Do not use terminal T/L3 on Inverters with single-phase input.
Model Terminal
Symbols
Screws Tightening
To rq ue
Nxm
Wires
Applicable Size Recommended
Size
Type
mm
2
AWG
mm
2
AWG
CIMR-
J7∗A
B0P1
R/L1, S/L2, T/L3,
-, +1, +2
M3.5 0.8 to 1.0 0.75 to 2 18 to 14 2 14 600 V vinyl-
sheathed or
equivalent
U/T1, V/T2, W/T3 1.24
(10.97)
CIMR-
J7∗A
B0P2
R/L1, S/L2, T/L3,
-, +1, +2
M3.5 0.8 to 1.0 0.75 to 2 18 to 14 2 14
U/T1, V/T2, W/T3 1.24
(10.97)
CIMR-
J7∗A
B0P4
R/L1, S/L2, T/L3,
-, +1, +2
M3.5 0.8 to 1.0 0.75 to 2 18 to 14 2 14
U/T1, V/T2, W/T3 1.24
(10.97)
CIMR-
J7∗A
B0P7
R/L1, S/L2, T/L3,
-, +1, +2, U/T1,
V/T2, W/T3
M3.5 0.8 to 1.0 2 to 5.5 14 to 10 3.5 12
214
CIMR-
J7∗A
B1P5
R/L1, S/L2, T/L3,
-, +1, +2, U/T1,
V/T2, W/T3
M3.5 0.8 to 1.0 2 to 5.5 14 to 10 5.5 10
214