52
Operating at Low Speed
By inputting a JOG command and then a FORWARD (REVERSE)
RUN command, operation is enabled at the jog frequency set in n29.
When multi-step speed references 1, 2, 3 or 4 are input simultaneously
with the JOG command, the JOG command has priority.
Constant No. Name Setting
n29 Jog Frequency Initial setting: 6.0 Hz
n36 to n39 Jog References Set to 10 for any constant.
Frequency
reference
FWD (REV) RUN/STOP
Multi-step speed ref. 1
(terminal S3)
Multi-step speed ref. 2
(terminal S4)
Multi-step speed ref. 3
(terminal S5)
Time
(n21) 25.0 Hz
(n22) 30.0 Hz
(n23) 35.0 Hz
(n24) 40.0 Hz
(n25) 45.0 Hz
(n26) 50.0 Hz
(n27) 55.0 Hz
(n28) 60.0 Hz

Table of Contents