6. Programming Features
87
Note: 1. When reading is enabled (n77=1), this setting is not necessary.
2. This setting is not necessary unless read-prohibition is selected.
COPY Function
This function writes the constants stored inside the Digital Operator in
batch to the Inverter. Write-in is possible only for Inverters with the
same product series and power supply specifications.
Therefore, writing from 200 V Class to 400 V Class Inverters (or vice
versa), from V/f control mode to vector control mode Inverters (or vice
versa), or from VS mini to VS-606V7 Inverters are not possible.
The Constant Copy Function Selection (n76), Constant Read Selection
Prohibit (n77), Fault History (n78), Software Version No. (n79), and
hold output frequency are not written. vAE will appear (flashing) if the
capacities of the Inverters differ.
Press ENTER to continue writing (the COPY function).
Press STOP/RESET to stop the COPY function.
The following constants are not written if the Inverter capacities differ.
• Set Constant Read Pro-
hibited Selection (n77) to
read-disabled.
*2
• Change the constant No.
to n77 by pressing the
or key.
• Press ENTER to display
the set value.
• Change the set value to 0
by pressing the or
key.
• Press ENTER.
(Lit)
(Flashes)
(Lit for one second.)
↓
(The constant No. is displayed.)
Constant No. Name Constant No. Name
n09 to n15 V/f Settings n64 Motor Rated Slip
n32 Motor Rated Current n65 Motor No-load
Current
n46 Carrier Frequency
Selection
Explanation Operator Display