EasyManua.ls Logo

YASKAWA VS MINI J7 series - Holding Acceleration;Deceleration Temporarily

YASKAWA VS MINI J7 series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
Holding Acceleration/Deceleration Temporarily
To hold acceleration or deceleration, input an ACCELERATION/
DECELERATION HOLD command. The output frequency is main-
tained when an ACCELERATION/DECELERATION HOLD command
is input during acceleration or deceleration.
When the STOP command is input while an ACCELERATION/
DECELERATION PROHIBITION command is being input, the accel-
eration/deceleration hold is released and operation ramps to a stop.
Set a Multi-function Input Selection (n36 to n39) to 16 (acceleration/
deceleration prohibit).
Time Chart for ACCELERATION/DECELERATION HOLD
Command Input
Note: If a FWD (REV) RUN command is input at the same time as an
ACCELERATION/DECELERATION HOLD command, the motor will
not operate. However, if the Frequency Reference Lower Limit (n31) is
set to a value greater than or equal to the Min. Output Frequency (n14),
the motor will operate at the Frequency Reference Lower Limit (n31).
FWD (REV)
RUN Command
ACCELERATION/
DECELERATION
HOLD Command
Frequency
Reference
Output
Frequency
FREQUENCY
AGREE
Signal

Table of Contents

Related product manuals