74
Initial Settings
• FREQUENCY AGREE Signal (setting=2)
11 Base blocked Closed when the Inverter output
is OFF.
-
12 Operating mode Closed when LOCAL is selected
for the LOCAL/REMOTE selec-
tion.
-
13 Inverter operation ready Closed when an Inverter fault is
not detected, and operation is
ready.
-
14 Fault restart Closed during fault retries. -
15 UV Closed when undervoltage is de-
tected.
-
16 Reverse run Closed during reverse run. -
17 Speed search Closed when Inverter conducts a
speed search.
-
18 Data output from com-
munications
Operates multi-function output
terminal independently from In-
verter operation (by MEMOBUS
communications)
83
No. Terminal Initial Setting
n40 MA, MB 1 (operating)
Setting Name Description Ref.
Detection width
±2 Hz
Release Width
±4 Hz
Output Frequency
FREQUENCY AGREE Signal