86
READ Function
Reads out the constants in batch from the Inverter and stores them in
EEPROM inside the Digital Operator. When the read-out is executed,
the previously stored constants data in the EEPROM are cleared and
replaced with the newly entered constants.
Example: Storing Constants from Inverter in EEPROM in Operator.
Explanation Operator Display
Enable the setting of con-
stants n01 to n79.
Press DSPL to light
[PRGM].
Press ENTER to display
the set value.
Change the set value to 4
by pressing the or
key.
• Press ENTER.
(May be a different constant No.)
(Lit)
(May be a different set value.)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
Set Constant Read Pro-
hibited Selection (n77) to
read-enabled.
*1
Change the constant No.
to n77 by pressing the
or key.
Press ENTER to display
the set value.
Change the set value to 1
by pressing the or
key.
• Press ENTER.
(Lit)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
• Execute read-out (READ)
using the Constant Copy
Function Selection (n76).
Change the constant No.
by pressing the or
key.
Press ENTER to display
the set value.
Change the set value to
rEd by pressing the or
key.
• Press ENTER.
Press DSPL or ENTER.
(Lit)
(Lit)
(Flashes while executing the
read)
(End is displayed after the read
has been completed.)
(The constant No. is displayed.)

Table of Contents