Example: Writing Constants from EEPROM in Operator to Inverter
A setting range check and matching check for the written constants are
executed after the constants are written from the Digital Operator to the
Inverter. If a constant error is found, the written constants are discarded
and the constants stored before writing are restored.
When a setting range error is found, the constant No. where an error
occurs is indicated by flashing.
When an inconsistency in the settings is found, (: a number)
is indicated by flashing.
Explanation Operator Display
Enable the settings for
constants n01 to n79.
Press DSPL to light
[PRGM].
Press ENTER to display
the set value.
Change the set value to 4
by pressing the or
key.
• Press ENTER.
(May be a different constant No.)
(Lit)
(May be a different set value.)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
• Execute write-in
(COPY) using the Con-
stant Copy Function
Selection (n76).
Change the constant No.
to n76 by pressing the
or key.
Press ENTER to display
the set value.
Change the set value to
CPy by pressing the or
key.
• Press ENTER.
Press DSPL or ENTER.
(Lit)
(Lit)
(Flashes while executing the
copy.)
(End is displayed after the copy
has been completed.)
(The constant No. is displayed.)