42
Following is an example in which the function LEDs are used to set fre-
quency reference, acceleration time, deceleration time, and motor direc-
tion.
Operation Steps Operator
Display
Function
Indicators
Status
Indicators
1. Turn ON the power supply. 0.0
2. Set constant n03 to 1. 1
3. Set the following constants.
n16: 15.0 (Acceleration Time)
n17: 5.0 (Deceleration Time)
15.0
5.0
4. Select forward or reverse run by pressing
the or key.
Examine the application. (Never
select REV when reverse run is pro-
hibited.)
(Forward)
or
(Reverse)
5. Set the reference by pressing the or
key.
60.0
6. Press . 0.0 to 60.0
7. Press to stop.
60.0 to 0.0