96
Inverters with Width of 108 mm
1. Removal
1. Remove the front cover, and
then remove the cooling fan
connector (CN4).
2. Press the right and left
catches on the fan cover in
direction 1, and pull the fan
cover in direction 2 to
remove it from the Inverter.
Pull out the wiring from the
cable lead-in hole at the bot-
tom of the plastic case.
3. Open the right and left sides
of the fan cover to remove
the cover from the cooling
fan.
2. Mounting
1. Mount the cooling fan on
the fan cover. The arrow
mark to indicate the airflow
direction must be opposite
to the cover.
2. Mount the fan cover on the
Inverter. Always mount the
right and left catches on the
fan cover on the heatsinks.
Thread in the wiring from
the cable lead-in hole at the
bottom of the plastic case to
the inside of the Inverter.
3. Connect the wiring to the
cooling fan connector (CN4)
and mount the front cover
and the terminal cover.
Cooling
Fan Wire
Airflow Direction
Cable
Lead-in
Hole