5-11
IM AQ6370E-02EN
Maintenance
5
No. Message Cause of Warning
148 RBW calibration failed. (Spectrum) Rms resolution calibration cannot be executed because the light
source spectrum width is too wide.
149 RBW calibration failed. (Stability) Rms resolution calibration cannot be executed because the light
source level is unstable.
154 Incompatible file type The file could not be loaded because the model does not support it.
170 Invalid character An illegal character was entered for a network name.
171 Invalid address An illegal address was set to an IP address.
172 Incompatible firmware version Attempted to load an incompatible update file.
173 Update file read error An incorrect number of files or file corruption was found when
attempting to load the update file.
174 Invalid password The password entered for the key lock is not correct.
175 Re-enterd password unmatched The two passwords entered for the key lock do not match.
176 Enter 4-digit number for password The password entered for the key lock is not a 4-digit number.
177 Invalid port number An attempt was made to set the port number for remote control to
an invalid number (1025, 20001, 30001).
180 APP: File not found There is no valid update file for installing an application.
181 APP: File format error The application update file format is incorrect.
182 APP: File data error The application update file data is incorrect.
183 APP: Out of storage space There is not enough free space to install the application.
184 APP: File operation error A file operation error occurred during application installation.
185 APP: Unexpected error An unexpected error occurred during application installation.
No. 200 - 299: Warnings for hardware failures
200 Fan motor stopped The fan motor (main unit) stopped. Automatically shuts down after
10 seconds from occurrence.
201 Calibration data failed Started up in emulation mode because there was a problem with
the instrument’s calibration data.
204 Calibration data failed There is an error in the instrument’s calibration data.
205 Internal communication error An abnormality occurred during instrument-internal communication.
206 Internal communication error An abnormality occurred during instrument-internal communication.
207 Abnormal internal temperature Internal temperature is abnormally high. Automatically shuts down
after 10 seconds from occurrence.
210 Internal Temparature warning Warning for rising internal temperature.
211 Auto offset error Obtained an abnormal value during AUTO OFFSET operation.
212 Auto offset error Obtained an abnormal value during AUTO OFFSET operation.
213 Auto temperature control error Problem with the light detector temperature control.
214 Measurement sequence error The sweep stopped because measurement sequence fell into
disorder during the sweep.
215 System optimization required System optimization is required. Restart the system.
220 Boot sequence error Started up in emulation mode because an abnormality occurred
upon start-up
221 Boot sequence error Started up in emulation mode because an abnormality occurred
upon start-up
222 Emulation mode. Entered emulation mode because an abnormality occurred.
223 Boot sequence error! Started up in emulation mode because an abnormality occurred
upon start-up
224 Internal communication error An abnormality occurred during instrument-internal communication.
225 Internal communication error An abnormality occurred during instrument-internal communication.
226 Internal communication error An abnormality occurred during instrument-internal communication.
227 Internal communication error An abnormality occurred during instrument-internal communication.
228 Memory allocation error Data memory initialization failed.
230 Monochromator error Entered emulation mode because an abnormality with the operation
of the monochromator occurred.
231 Monochromator error Entered emulation mode because an abnormality with the operation
of the monochromator occurred.
232 Monochromator error Entered emulation mode because an abnormality with the operation
of the monochromator occurred.
233 Monochromator error Entered emulation mode because an abnormality with the operation
of the monochromator occurred.
5.7 Warning Display Function