<9. Approvals>
75
IM 01E20A01-01EN
9. Approvals
This chapter describes further requirements and notices
concerning the approval. The description in this chapter is
prior to other description in this User’s Manual.
(1) PED (Pressure Equipment Directive)
(AXF Integral Flowmeter),
(AXF Remote Flowtube)
Technical Data
Module: H
Type of Equipment: Piping
Type of Fluid: Liquids and gas
Group of Fluid: 1 and 2 (*4)
General-purpose Use / Submersible Type / Explosion Proof
Type
MODEL
DN
(mm) (*1)
PS
(MPa) (*1)
PS DN
(MPa • mm)
CATEGORY
(*2) (*4)
AXF002G
2.5 4 10
Sound Engineering
Practice (SEP) (*3)
AXF002C
AXF005G
5 4 20
Sound Engineering
Practice (SEP) (*3)
AXF005C
AXF010G
10 4 40
Sound Engineering
Practice (SEP) (*3)
AXF010C
AXF015G
15 4 60
Sound Engineering
Practice (SEP) (*3)
AXF015C
AXF015W
AXF025G
25 4 100
Sound Engineering
Practice (SEP) (*3)
AXF025C
AXF025W
AXF032G
32 4 128 IIAXF032C
AXF032W
AXF040G
40 4 160 IIAXF040C
AXF040W
AXF050G
50 4 200 IIAXF050C
AXF050W
AXF065G
65 2 130 IIAXF065C
AXF065W
AXF080G
80 2 160 IIAXF080C
AXF080W
AXF100G
100 2 200 IIAXF100C
AXF100W
AXF125G
125 2 250 IIAXF125C
AXF125W
AXF150G
150 2 300 IIAXF150C
AXF150W
AXF200G
200 2 400 IIIAXF200C
AXF200W
AXF250G
250 2 500 IIIAXF250C
AXF250W
AXF300G
300 2 600 IIIAXF300C
AXF300W
AXF350G
350 1 350 IIAXF350C
AXF350W
AXF400G
400 1 400 IIIAXF400C
AXF400W
Sanitary Type
MODEL
DN
(mm) (*1)
PS
(MPa) (*1)
PS DN
(MPa • mm)
CATEGORY
(*2) (*4)
AXF015H 15 1 15
Sound Engineering
Practice (SEP) (*3)
AXF025H 25 1 25
Sound Engineering
Practice (SEP) (*3)
AXF032H 32 1 32 I
AXF040H 40 1 40 I
AXF050H 50 1 50 I
AXF065H 65 1 65 I
AXF080H 80 1 80 I
AXF100H 100 1 100 I
AXF125H 125 1 125 II
*1: PS: Maximum allowable pressure for Flowtube
DN: Nominal size
*2: For details, refer to the following.
Table 6 covered by ANNEX II of Directive 97/23/EC
(untilJuly18th,2016)
Table 6 covered by ANNEX II of Directive 2014/68/EU
(fromJuly19th,2016)
*3: Article 3, paragraph 3 of Directive 97/23/EC
(untilJuly18th,2016)
Article 4, paragraph 3 of Directive 2014/68/EU
(fromJuly19th,2016)
*4: ModelsclassiedincategoriesIorIIshallnotbeusedfor
unstable gases of Group 1.
• Installation
WARNING
Tighten the bolts of the piping joints according to
the prescribed torque values.
• Takemeasurestoprotecttheowmetersfrom
forces caused by vibration channeled through the
piping.
• Operation
WARNING
The instrument should be operated with the
temperatureandpressureoftheuidunder
normal operating conditions.
The ambient temperature should be that of normal
operating conditions.
Take measures to prevent excessive pressure
such as water hammer, etc. To avoid water
hammer prevent the pressure from exceeding the
PS (maximum allowable pressure) by setting the
system’s safety valves, etc. appropriately.
• Shouldexternalreoccur,takesafetymeasuresat
the device itself or system-wide prevent it having
aneffectontheowmeters.
• Avoidusinguidsexceedingthecorrosionproof
limitations of the lining and electrodes.
Take measures not to abrade the metal pipe, and
avoidabradingtheliningbyusinguidssuchas
slurry and sand are contained.
Approvals
9

Questions and Answers: